Brocade Communications Systems Upgrade Pef IPMC5000PEF IPMC5000PEF Manual De Usuario

Descargar
Página de 230
-------------------------------------------------------------------------------
1     ff07::c:1       3200:12::32
2     ff07::c:2       3200:12::32
3     ff07::c:3       3200:12::32
Number of group-to-RP mappings: 3
Brocade#
Syntax: show ipv6 pim vrf vrf-name ] rp-map
The vrf parameter allows you to display IPv6 RP-to-group-mappings for the VRF instance identified by
the vrf-name variable.
The following table displays the output from the show ipv6 rp-map command.
Output from the show ipv6 pim rp-map command
TABLE 31   
Field
Description
Index
The index number of the table entry in the display.
Group address
Indicates the IPv6 PIM Sparse multicast group address using the listed RP.
RP address
Indicates the Iv6 address of the Rendezvous Point (RP) for the listed PIM Sparse group.
Displaying RP information for an IPv6 PIM Sparse group
To display RP information for an IPv6 PIM Sparse group, enter the following command at any CLI level.
device# show ipv6 pim rp-hash ff1e::1:2
  RP: 2001:3e8:255:255::17, v2
    Info source: 2001:3e8:255:255::17, via bootstrap
Syntax: show ipv6 pim vrf vrf-name ] rp-hash group-addr
The vrf parameter allows you to display RP information for a PIM Sparse group for the VRF instance
identified by the vrf-name variable.
The group-addr parameter is the address of an IPv6 PIM Sparse IP multicast group.
The following table displays the output from the show ipv6 pim rp-hash group-addr command.
Output from the show ipv6 pin rp-hash group-addr command
TABLE 32   
Field
Description
RP
Indicates the IPv6 address of the Rendezvous Point (RP) for the specified IPv6 PIM Sparse group.
Following the IPv6 address is the port or virtual interface through which this device learned the identity
of the RP.
Info source Indicates the IPv6 address on which the RP information was received. Following the IPv6 address is
the method through which this device learned the identity of the RP.
Displaying the RP set list
To display the RP set list, enter the show ipv6 pim rp-set command at any CLI level.
device# show ipv6 pim rp-set
Static RP
Displaying RP information for an IPv6 PIM Sparse group
FastIron Ethernet Switch IP Multicast Configuration Guide
183
53-1003085-02