Inner Door Installation with Gasket 
Step 1. 
Clean any residual gasket residue or other debris from the combustion 
chamber surface before installing the inner door/gasket assembly. 
Step 2.
Place the left side inner door into position first, being sure to firmly 
position the concave channel of the inner door around the feedline. 
Step 3. 
Using the 1/4” hex drive screws removed in Step 5 of the Inner Door 
Removal Procedure on page 32, secure the left side inner door in place.  Do not over-
tighten the screws. 
Step 3. 
Position the pilot tube and spark igniter wire against the left side inner 
door flange gasket.  Do not route these through the concave channel with the feedline. 
Step 4. 
Firmly place the right side inner door flange against the left side inner
door flange. 
Step 5. 
Using the 1/4” hex drive screws removed in Step 4 of the Inner Door 
Removal Procedure on page 32, secure the two flanges together.  Do not over-tighten 
the screws. 
Step 6. 
Align the right side inner door to the combustion chamber and verify the 
fastener holes of the combustion chamber are aligned with the right side inner door
slotted openings.  Verify seal integrity around the combustion chamber opening.
Step 7. 
Using the 1/4” hex drive screws removed in Step 3 of the Inner Door 
Removal Procedure on page 32, secure the right side inner door.  Do not over-tighten 
the screws.  Verify that both the left and right side inner doors are properly positioned 
and sealed against the combustion chamber. 
Step 8.  
Re-install the outer door. 
Step 9. 
To resume operation, follow the instructions located on the water heater 
lighting instruction label.  Or, use the lighting instructions located in the water heater 
installation and operating manual.
Inner Door Installation 
WARNING
Stripped fastener connections may allow for an inner door seal breach.  A seal breach may 
result in a fire or explosion, causing property damage, personal injury, or death.  Do not 
over tighten screws.  If a fastener connection is stripped, contact the manufacturer listed 
34