Bradford-White Corp D4504S*F(BN Manual De Usuario

Descargar
Página de 40
Page 8 
Ignition State 
Timing 
Adjust Damper Position and Verify (Open Posi-
tion) 
15 seconds 
Trial for Ignition 
90 seconds 
Flame Stabilization Period
3 seconds 
Re-adjust Damper Position and Verify 
15 seconds 
Flame Failure Response Time 
1.5 seconds (2 second maximum; 1 second mini-
mum)
Adjust Damper Position and Verify (Closed Po-
sition) 
15 seconds 
Damper Blade Position Fault (failed open/close) 
Retry after 2 minutes 
Soft Lockout 
Retry after 5 minutes 
ECO Limit Lockout 
Indefinite (See page 11 to reset) 
Verify Resistive Delay 
Retry after 2 minutes (repeats 5 times) 
Simulated Resistive Load Lockout 
Indefinite (cycle power to reset) 
Hardware Error Lockout 
Indefinite (self clears if fault clears for at least 15 
seconds)
Specifications
Wiring Diagram
Control Timings
8