4-4
SilkWorm 4016 Hardware Reference Manual
Publication Number: 53-1000175-01
Interpreting LED Activity
4
Interpreting LED Activity
Each SilkWorm 4016 uses LEDs to indicate status. These LEDs are shown in 
. Not shown are 
the two LEDs adjacent to each SFP, with one LED to indicate port speed and one LED to indicate 
activity.
Figure 4-1
LED Locations
Location
Indicator
Color
Operation
1 blade 
server 
chassis
green/amber
Controlled by the blade server. Refer to the blade 
serverdocumentation for details.
2
status
green/amber
Off: Switch is off or both power supplies from the 
PowerEdge 1855) or onboard DCC have failed
Green: No errors and all ports are ready for use
Amber: Boot-up state, port(s) offline, or in reset 
state
Blinking (2 Hz green/amber): One or more 
environmental ranges are exceeded, or error log 
contains diagnostic error messages
Note: The LED might blink during testing.
3
power green
Off: Switch is off or both power supplies (on the 
PowerEdge 1855) or onboard DCC have failed
Green: Normal operation and power supply is 
functioning properly. Power is supplied by the 
blade server chassis
10
11
12
13
14
15
!
1
2
3
4
5
6
7