Bosch Appliances Home Security System D7412G Manual De Usuario

Descargar
Página de 142
D9412G/D7412G | Program Entry Guide | 2.0 9000MAIN
EN | 34
Bosch Security Systems | 1/04 | 47775E
2.8
Miscellaneous
Duress Type
Default:
1
Selection:
1 or 2
1
Add 1 to the last digit to generate an alarm. For
example, if the passcode is 6123, 6124 triggers a
duress alarm.
If the last digit of the passcode is 0, a duress
alarm is generated when the user enters 1 as the
last digit of the passcode.
If the last digit of the passcode is 9, a duress
alarm is generated when the user enters 0 as the
last digit of the passcode.
2
Add 2 to the last digit to generate an alarm. For
example, if the passcode is 6123, 6125 triggers a
duress alarm.
If the last digit of the passcode is 8, a duress
alarm is generated when the user enters 0 as the
last digit of the passcode.
If the last digit of the passcode is 9, a duress
alarm is generated when the user enters 1 as the
last digit of the passcode.
This program item determines whether users add
one (+1) or two (+2) to the last digit of the passcode.
To activate a duress alarm, the user increases the
value of the last digit of their passcode when
entering it at the command center.
Duress is enabled/disabled by area in
Area Parameters.
The duress alarm is activated when a user
enters the duress combination followed by
the termination keys ([ESC] or [ENT]).
Cancel Report
Default:
No
Selection:
Yes or No
Yes
Send Cancel and Fire Cancel Reports
according to routing.
No
Do not send Cancel and Fire Cancel
Reports.
Use this program item to control whether or not
Cancel and Fire Cancel Reports are sent.
A Cancel and Fire Cancel Report is created when a
passcode is entered to silence an Alarm Bell or a
Fire Bell before the bell time expires.
2.9
Area Parameters
This programming module contains three
programming categories: Area Parameters, Bell
Parameters, and Open/Close Options.
2.9.1
Area Parameters
Area
Default:
1
Selection:
1 to 8
Enter the area number you are programming.
A# Area On
Default:
Yes (Area 1 only)
Selection:
Yes or No
Yes
Area is enabled.
No
Area is disabled.
Use this program item to enable or disable the area
specified.
0101
0101
0101
1.
 
When programmed No, points
assigned to this area do not generate
events.
Command centers with Area scope
which are assigned to this area
display 
AREA # DISABLED
.
When arming and disarming, this area
number is not displayed at control
centers with the scope to view this
area.
Status for this area is not reported
with Status Reports.
All user authority in this area is turned
off while the area is disabled.
2.
 
Area 1 must be enabled: System
events such as power and phone
supervision do not report properly if
Area 1 is disabled.