D9412G/D7412G | Program Entry Guide | 5.0 RADXSKED
EN | 98
Bosch Security Systems | 1/04 | 47775E
Table 32: Programming for Two Same Day Opening Windows (see Figure 4)
Open
Close
W#
Day of Week
Early
Begin
Start
Stop
Early
Begin
Start
Stop
eXcept
On
Holiday
Holiday
Index
Area(s)
1
S  M  T  W  T  F  S
06: 00
07 : 00
08: 00
Yes / No
1   2   3   4
1  2  3  4  5  6  7  8
2
S  M  T  W  T  F  S
13 : 00
14 : 00
15 : 00
Yes / No
1   2   3   4
1  2  3  4  5  6  7  8
Do not program a single window to cross the midnight boundary. The window stop time must be later than the
window start time. To program a window that effectively crosses the midnight boundary, you must program two
windows.
For example, to program windows for an area that opens between 11:30 PM and 12:30 AM, five days a week, use
two windows as shown in Table 33.
Table 33: Programming to Link Two Days over Midnight
Open
Close
W#
Day of Week
Early
Begin
Start
Stop
Early
Begin
Start
Stop
eXcept
On
Holiday
Holiday
Index
Area(s)
1
S  M  T  W  T  F  S
22 : 00
23 : 30
23 : 59
Yes    No
1   2   3   4
1  2  3  4  5  6  7  8
2
S  M  T  W  T  F  S
00 : 00
00 : 00
00 : 30
Yes    No
1   2   3   4
1  2  3  4  5  6  7  8
W# Close Early Begin
Default:
00: 00
Selection:
HH:MM (hours and minutes)
00:00 to 23:59
Close Early Begin: This program item is one of
three required to create a Closing Window. To finish
programming a Closing Window, Close Window
Start and Close Window Stop must be programmed.
Use Close Early Begin to set the time that you want
the control panel to look for a Closing Window.
When Opening and Closing Reports are enabled,
arming the area between midnight and the Close
Early Begin time generates a Closing Report. In
addition:
 
If Disable O/C in Window is Yes: Arming the
area between the Close Early Begin time and
the Close Window Start time generates a
Closing Early Event (if the Close Early Begin
time is the same as the Close Window Start
time, the Closing Early Event is not sent).
Arming the area between the Close Window
Start and Close Window Stop time creates a
local event in the Panel log but does not send
the Closing Report to the central station.
Arming the area after the Close Window Stop and
the next window’s Close Early Begin time (or
midnight, whichever comes sooner) generates a
Closing Late Event.
 
If Disable O/C in Window is No: Disarming
the area generates a Closing Report without the
early or late modifier, regardless of when the
area is armed.
When you are programming multiple windows
to activate on a single day, program the
windows in chronological order. Be careful not
to program a window’s Close Early Begin time
for a time that is between any other window’s
Close Window Start and Close Window Stop
time.
Disabled windows have a blank begin time. If
the entry for this prompt is blank, but times are
programmed for Close Window Start and Close
Window Stop, the window is disabled.
To disable the window, both the hours and
minutes spaces must be blank.
00:00 is midnight, 23:59 is 11:59 PM. Make
entries using a 24-hour clock (for example, 7:00
AM is entered as 07:00, 2:45 PM is entered as
14:45).