White Rodgers 1E78-140 White-Rodgers 70 Series Heat Only Thermostat Instruccion De Instalación

Descargar
Página de 4
2
Take care when securing and routing wires so they do 
not short to adjacent terminals or rear of thermostat. 
Personal injury and/or property damage may occur.
Do  not  use  on  circuits  exceeding  specified  voltage. 
Higher voltage will damage control and could cause 
shock or fire hazard.
Do  not  short  out  terminals  on  gas  valve  or  primary 
control  to  test.  Short  or  incorrect  wiring  will 
damage thermostat and could cause personal injury 
and/or property damage.
Thermostat  installation  and  all  components  of  the 
system  shall  conform  to  Class  II  circuits  per  the 
NEC code.
RH
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
G
W
Figure 2. Typical wiring diagram for
heat only,  2-wire, single transformer systems
TRANSFORMER
Heating
System
Y
RC
JUMPER
WIRE
O
B
ATTENTION! This product does not contain mercury. How-
ever, this product may replace a unit which contains mercury.
Do  not  open  mercury  cells.  If  a  cell  becomes  damaged,  do 
not touch any spilled mercury. Wearing non-absorbent gloves, 
take up the spilled mercury and place into a container which 
can be sealed. If a cell becomes damaged, the unit should be 
discarded.
Mercury must not be discarded in household trash. When the 
unit this product is replacing is to be discarded, place in a suit-
able container. Refer to www.white-rodgers.com for location to 
send product containing mercury.
WARNING
!
Hydronic (Hot Water or Steam)  
Heating Systems
This thermostat is set to operate properly with a forced-air heating 
system. If you have a hydronic heating system (a system that 
heats with hot water or steam), you must set the thermostat to 
operate properly with your system.
The factory default setting is forced air heat. Clipping jumper 
W905 on the circuit board will produce a longer heating cycle 
which is normally for hot water or steam (hydronic) systems. Both 
settings produce a very accurate temperature control and can 
be set to your personal preference. As received, the thermostat 
cycles the system just under 1°F. With W905 clipped, the system 
cycles at approximately 1.5°F.
Attach Thermostat Base to Wall
1.  Remove the packing material from the thermostat. Gently 
pull the body straight off the base. Forcing or prying on the 
thermostat will cause damage to the unit.
2.  Connect wires beneath terminal screws on base using ap-
propriate wiring schematic (see fig. 2).
3.  Place base over hole in wall and mark mounting hole loca-
tions on wall using base as a template.
4.  Move base out of the way. Drill mounting holes.
5.  Fasten base loosely to wall, as shown in fig. 1, using two 
mounting screws. Adjust until level, and then tighten screws. 
(Leveling is for appearance only and will not affect thermostat 
operation.) If you are using existing mounting holes, or if holes 
drilled are too large and do not allow you to tighten base 
snugly, use plastic screw anchors to secure subbase.
6.  Push excess wire into wall and plug hole with a fire-resistant 
material (such as fiberglass insulation) to prevent drafts from 
affecting thermostat operation.
Battery Location
This thermostat requires 2 “AAA” alkaline batteries to operate.
 
If 
 appears on the display, the batteries are low 
and should be replaced with fresh “AAA” Energizer
®
 alkaline 
batteries. The batteries are located on the back of the thermostat 
body (see fig. 1). 
 
New Thermostat 
  Other Manufacturers’
  Terminal Designation 
  Terminal Designation
 
RH 
RH 
M
 
H
TERMINAL CROSS REFERENCE CHART
CAUTION
!
3
  REMOVING OLD THERMOSTAT
 
continued from first page
4
  MOUNTING AND WIRING