White Rodgers 1F81-261 White-Rodgers 80 Series Programmable Multi-stage Thermostat Referencia De Cableado

Descargar
Página de 1
www.white-rodgers.com
8
TECHNICAL HELP
C*
R
Y2
Compressor
Contactor
Stage 1
Heat
Relay
Stage 1
Heat
Relay
Stage 2
Thermostat
Control
Circuit
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
Y
W
W2
Typical wiring diagram for single transformer systems
Fan
Relay
G
TRANSFORMER
Compressor
Contactor
Stage 2
* The 24 Volt neutral connection 
to terminal 
C on the thermostat 
is not required if you replace 
the batteries once a year with 
fresh “AA” Energizer
®
 alkaline 
batteries. 
1F81-261
1F83-261
CONFIGURATION AND
TYPICAL WIRING DIAGRAMS
1
 
 
 
Displayed (Factory Default)  Press          or          to select:            
COMMENTS
HOLD
(0:00)
0 to 8 hrs (in 
15 minute increments)
2
(FA)
SL
Select temporary Hold time
4
5
E
(ON)
OFF
6
7
 LOC
(OFF)
ON
0 HI
(0)
4 LO to
4 HI
°(F)
°C
Returns to normal operation
9
10
Select Energy Management Recovery OFF or ON
Select compressor lockout OFF or ON
Select temperature display adjustment higher or lower
Select temperature display to  °F or  °C
Select ON to start 2nd stage immediately when the setpoint
is manually raised more than 3
°  F in HEAT or lowered more
than 3
°  F in COOL from room temperature
RUN
PRGM
and
 RUN
HOLD*
HOLD*
3
d-L
(ON)
OFF
OFF
Select display backlight OFF or ON
HOLD*
HOLD*
Filter
(000)
0 to 1950 hours
(in 50 hour increments)
Select filter replacement run time
HOLD*
HOLD*
HOLD*
Select FA or SL (Fast or Slow) heating cycle rate
Configuration Menu
* Press 
HOLD to advance to next item or TIME to move backwards to previous item
1 + 2
FA
(ON)
8
1F83-261
Press Button(s)
1F81-261
Press Button(s)
Step
HOLD*
N/A
N/A
N/A
Set
 SYSTEM
switch to OFF
and Press
and
and
and
and
and
and
Set
 SYSTEM
switch to 
HEAT
or 
COOL
C*
R
Y2
Compressor
Contactor
Stage 1
Heat
Relay
Stage 1
Heat
Relay
Stage 2
Thermostat
Control
Circuit
24 VAC
120 VAC
Hot
Neutral
THERMOSTAT
SYSTEM
Y
W
W2
Typical wiring diagram for two-transformer systems with NO safety circuits
Fan
Relay
G
TRANSFORMER
Compressor
Contactor
Stage 2
24 VAC
120 VAC
Hot
Neutral
TRANSFORMER
TWO COMMONS MUST
BE JUMPERED TOGETHER!
CUT AND
TAPE OFF!
* The 24 Volt neutral connection 
to terminal 
C on the thermostat 
is not required if you replace 
the batteries once a year with 
fresh “AA” Energizer
®
 alkaline 
batteries. 
NOTE
The following wiring diagrams show typical terminal identification and wiring. For proper installation, refer to the original manufacturer’s instruc-
tions.
Relay contacts shown are thermostatically operated.
Reset Operation: 1F81-261
If a voltage spike or static discharge 
blanks out the display or causes er-
ratic thermostat operation, you can 
reset the thermostat by pressing 
 and TIME at the same time. This 
also resets the factory defaults to the 
configuration menu and program. If the 
thermostat has power, has been reset 
and still does not function correctly, 
contact your heating/cooling service 
person or place of purchase.
Reset Operation: 1F83-261
If a voltage spike or static discharge 
blanks out the display or causes erratic 
thermostat operation, you can reset the 
thermostat by pressing 
 and 
move the SYSTEM switch from OFF 
to HEAT at the same time. This also 
resets the factory defaults to the 
configuration menu
. If the thermostat 
has power, has been reset and still 
does not function correctly, contact 
your heating/cooling service person or 
place of purchase.