White Rodgers 1F95-0671 Manual De Usuario

Descargar
Página de 16
5
Programming and Confi guration Items 
1
  "System On" indicates when heating or cooling stage
 is 
energized. 
"System On +2" indicates when addi 
 
 
tional stages are on.
2
 
The word "Hold" is displayed when the thermostat is
 in 
the 
HOLD mode. "Temp" is displayed when the
 
thermostat is in a Temporary HOLD mode.
3   Displays "Change Filter" when the system has run for
 the 
programmed 
fi lter time period as a reminder to
 
change or clean your fi lter.
4   Displays "Set" for setpoint when in Run Program mode.
5
 
Displays System Mode (Heat, Em, Auto, Cool, Off) 
 
or Time in menu mode.
6
 
Displays Fan mode (On, Auto) "Prog FAN On" or    
 
"Run Sched" in Menu mode.
THERMOSTAT QUICK REFERENCE
Home Screen Description
Figure 5 – Home Screen Display
Figure 6 – Programming & Confi guration Items
7
 
Displays "Run Schedule""Schedule", or "Menu".
8
 
Displays "Save" when Cool Savings
TM
 is working.
9
 
Displays "Heat Pump" when system is confi gured
 
as Heat Pump thermostat.
10
 
Displays "Hold" in programmable mode when not in
 
Hold mode. Displays Light Bulb in non-program-     
 mable 
mode.
11
 
Initially displays "Auto Sched". If Auto Schedule had
 
been used or disabled, then it displays "Cool Savings"
 
when in the Cool Mode. Displays "Copy" in Schedule  
 mode 
and 
"Fan" in Fan Schedule mode.
12
 
"Call For Service" indicates a diagnostic fault in the   
 
heating/cooling system, it does not indicate a fault in the
 thermostat.
13   "Keypad Lockout" in Menu mode when selecting key- 
 
pad Lockout or in RUN when a keypad Lockout is active.
Room
Temperature
Setting
Temperature
System
Indicator
Fan
Indicator
Battery Level Indicator 
Indicating the current power level
of the 2 “AA” batteries:
 
    Full power remaining.
 
    Half power remaining
Change           The batteries should
be replaced at this time with 2 new
premium brand “AA” Alkaline batteries.
(See page 2 for more details)
  
11
10
7
6
5
13
9
1
3
12
8
2
4