White Rodgers 1F95-0680 Manual De Usuario

Descargar
Página de 16
5
INSTALLER/CONFIGURATION MENU
Press and hold the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to ad-
vance to the next menu item. Press 
 or 
 to change a menu item options. 
INSTALLER/CONFIGURATION MENU
MENU
REF.
HP SS
PRESS
BUTTON
DISPLAYED 
(FACTORY DE-
FAULT)
Press 
 or 
 to
select from listed op-
tions
COMMENTS
1
1
1
MENU
(MS 2)
HP 1, HP 2, SS 1
Selects Multi-Stage (MS 2 No Heat Pump), 
 Heat Pump 1 (HP 1, 1 compressor), 
 
Heat Pump 2 (HP 2, 2 compressor or 2
  speed compressor), or Single Stage (SS 1)
2
2
2
MENU
(GAS) for SS or MS
ELE
GAS setting: furnace controls the blower
ELE setting: thermostat controls the blower
3
3
3
MENU
CS (3)
0, 1, 2, 4, 5, 6
Selects Cool Savings
Value 1 (low) to 6 (high), 
Value 0 disables feature
4
4
4
MENU
E (On)
OFF
Selects Energy Management Recovery (EMR)
On or OFF. 
5
5
MENU
CR Heat (ME)
SL, FA
Adjustable Anticipation:
Selects heating cycle rate for MS or SS in #1 only
6
5
MENU
CR Heat Pump
(ME)
SL, FA
Adjustable Compressor Anticipation 
(Heat Pump) [only when heat pump (Heat/Cool) 
selected in #1]
7
6
6
MENU
CR Cool (ME)
or
CR Au (FA)
SL, FA
SL
Adjustable Anticipation:
Selects the cycle rate for cooling (only when
MS 2 or SS 1 is selected in item 1.) or
Selects the cycle rate for Emergency mode
and Auxiliary stage if Heat Pump is selected
in item 1.
8
7
7
MENU
CL (OFF)
CL On
Compressor Lockout Time
9
8
8
MENU
  Cool Off, Em Heat 
Auto
Heat Auto Cool Off,
Heat Off with Fan icon,
Heat Off without Fan icon
Cool Off, Auto Off
System Mode Confi guration
with Automatic Changeover capability
10
9
9
MENU
dL (On)
dL OFF
Selects Display Light On or OFF
11
10
10
MENU
0
(current temperature)
1 HI, 2 HI, 3HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
Adjustable Ambient Temperature Display
12
11
11
MENU
°F
°C
Selects Fahrenheit/Celsius Temperature Display
13
12
12
MENU
(On) b
OFF
May select Beeper OFF to stop audible 
key feedback               
14
13
13
MENU
P (7)
3, 0
Defaults 7-day programming (P7) but non-
programmable (0) or 5/1/1 programming (P3)
is available on most models. 
15
14
14
MENU
PS (2)
4
Selects Program periods per day: 
4 = Morn, Day, Eve, Night
2 = Day, Night
16
15
15
MENU
Heat AS (On)
OFF
Automatic Schedule for heat mode 
17
16
16
MENU
Cool AS (On)
OFF
Automatic Schedule for cool mode
18
17
MENU
Heat FA (On)
OFF
Fast Heat option may be disabled by
selecting OFF. NA to SS or HP1 confi g.
19
18
MENU
Cool FA (On)
OFF
Fast Cool option may be disabled by
selecting OFF. NA to SS or HP1 confi g.
20
19
17
MENU
Remote (OFF)
On
Selects Remote Sensor On/OFF
MENU
Remote
(In)
Outdoor
Selects Remote Sensor to outdoor
NA is Remote Sensor OFF
MENU
Indoor Loc 
(On)
OFF
Selects Local Sensor (in thermostat) to OFF. 
N/A if Remote is selected to Outdoor