White Rodgers 1F90-71 Guía De Operación

Descargar
Página de 36
21
Heating Program for ALL days of the Week:
FACTORY PREPROGRAMMING
Cooling Program for ALL Days of the Week:
PERIOD
TIME
TEMP
PERIOD
TIME
TEMP
MOR
DAY
EVE
NHT
5:00 AM
9:00 AM
4:00 PM
10:00 PM
70
70
70
64
MOR
DAY
EVE
NHT
5:00 AM
9:00 AM
4:00 PM
10:00 PM
78
82
78
78
Now look at the factory preprogrammed times
and temperatures shown below. If this program
will suit your needs, simply press 
RUN
PRGM
 to begin
running the factory preset program.
If you want to change the preprogrammed times
and temperatures, do the following.
To operate properly in the AUTO mode, there
must be a minimum 1
°
F separation between
the highest heat temperature and the lowest
cool temperature (see diagram at right).
Determine the time periods and heating and
cooling temperatures for your weekday pro-
gram. You must program 4 periods for each day
(MOR,  DAY,  EVE, and NHT). However, you
may use the same heating and cooling tempera-
tures for consecutive time periods. You can
choose start times, heating temperatures, and
cooling temperatures independently for both
NOTE
79
78
77
76
75
74
73
COOLING TEMPERATURES
HEATING TEMPERATURES
DEAD BAND 1
°
F