SERVICE (cont.)
10860  061501
LIMIT THERMOSTAT
P1161.40
FIG. 4 LIMIT THERMOSTAT
Location:
 
The limit thermostat is located inside the rear of
the hood on the tank lid.
Test Procedures:
1.  Disconnect the brewer from the power source.
2.  Disconnect the blue and black wires from the limit 
thermostat.
3.  With an ohmmeter, check for continuity across 
the limit thermostat terminals.
If continuity is present as described, the limit thermostat 
is operating properly.
If continuity is not present as described, replace the 
limit thermostat.
Removal and Replacement:
1.  Remove  all  wires  from  limit  thermostat  termi-
nals.
2.  Carefully slide the limit thermostat out from under 
the retaining clip and remove limit thermostat.
3.  Carefully slide the new limit thermostat into the 
retaining clip.
4.  Refer to Fig. 5 when reconnecting the wires.
P1800
BLK to Terminal Block or Tank Heater Switch
BLU to BLU Lead from 
Control Thermostat