WARMER ELEMENT(S)
P1167
SERVICE (cont.)
Location:
 
The warmer element(s) is located under the   warmer 
plate.
Test Procedures:
1.  Disconnect the brewer from the power source.
2.  With a voltmeter, check voltage across the white 
wire to the power cord and the white/red, brown/
black or violet wire to the "ON/OFF" switch, with 
the "ON/OFF" switch in the "ON" (upper) position. 
The indication must be:
 
a) 100 volts ac for two wire 100 volt models.
 
b) 120 volts ac for two wire 120 volt models.
3.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to Wiring 
Diagrams and check brewer wiring harness.
4.  Check the continuity across the two terminals on  
the warmer element.
If continuity is present as described, reconnect the 
white wire and white/red, brown/black or violet wires 
on the warmer element.
P1164
If continuity is not present as described, replace the 
warmer element.
Removal and Replacement:
1.  Remove  the  three  #4-40  screws  securing  the 
warmer assembly to the brewer.
2.  Lift the warmer assembly from the brewer.
3.   Disconnect the two wires from the warmer element 
terminals.
4.  Remove the two #8-32 nuts securing the warmer 
element to the warmer plate.
5.  Securely install new warmer element.
6.  Reconnect the two wires to warmer element ter-
minals.
7.  Securely install warmer assembly on the brewer.
8.  Refer to the illustration below when reconnecting 
the wires. 
FIG. 13 WARMER ELEMENT TERMINALS
WHI to WHI Lead on Power Cord (120V Brewers)
WHI to Terminal Block (100V Brewers)
WHI/RED to ON/OFF Switch (One Lower Warmer)
BRN/BLK to ON/OFF Switch (to Front Warmer or 
Side Warmer)
VIO to ON/OFF Switch (Top Rear Warmer or Rear 
Side Warmer)