SERVICE (cont.)
BREW TIMER
FIG. 6 BREW TIMER
P2143.35
Location:
 
The brew timer is located in the hood.  It consists 
of the dial plate and circuit board.
Test Procedure:
1.  Disconnect the brewer  from the power source.
2.  Remove the wires from terminals TL3, TL4, & TL5 
of the timer and rotate the dials fully counterclock-
wise.
3.  With a voltmeter, check the voltage across ter-
minals TL1 and TL2  when the ON/OFF switch is 
in the “ON” position. Connect the brewer to the 
power source.  The indication must be:
 
a) 120 volts ac for 2-wire 120 volt models.
  b) 120 volts ac for 3-wire 120/208 and 120/240 
volt models.
4.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the Wir-
ing Diagram and check the wiring harness.
5.  Check for continuity across the white/orange and 
white/yellow wires when the start switch is held 
in the lower position.
If continuity is present as described, reconnect the 
wires to terminals TL3, TL4, & TL5 of the timer board 
and proceed to #6.
If continuity is not present as described, refer to the 
Wiring Diagram and check the wiring harness.
6.  With a voltmeter, check the voltage across termi-
nals TL1 and TL4 when the ON/OFF switch is in the 
“ON” position and the start switch is momentarily 
placed in the lower position.  Connect the brewer 
to the power source. The indication must be:
 
a) 120 volts ac for 2-wire 120 volt models for  
approximately twenty seconds and then return  
to its previous indication.
  b) 120 volts ac for 3-wire 120/208 and 120/240 
volt models for approximately twenty seconds and 
then return to its previous indication.
7.  Disconnect the brewer from the power source.
If voltage is present as described, the timer is operat-
ing properly.  Adjust the timer dials as required.
If voltage is not present as described, replace the timer.
Removal and Replacement:
1.  Remove all wires from the timer.
2.  Remove the circuit board and dial plate from the 
brackets.
3.  Install the new dial plate and circuit board to the 
brackets.
4.  Refer to Fig. 7 when reconnecting the wires.
5.  Adjust the timer dials as required.
FIG. 7 BREW TIMER TERMINALS
10777 041500
4
2
3
1
MI
NU
TE
S
MIN
UT
ES
BU
NN
-O
-M
AT
IC
P/N
  0
57
91
-00
06
 12
0 V
AC
5
3
6
4
7
5
6
6
7
8
TL3-WHI/ORA to Start Switch
TL2-WHI to ON/OFF Switch
TL2-WHI to Terminal Block
TL1-WHI/VIO to Brew Solenoid Valve
TL1-WHI/VIO to ON/OFF Switch
TL4-WHI/GRN to Brew Solenoid Valve
TL5-WHI/YEL to Start Switch