SERVICE (cont.)
TANK HEATER 
FIG. 20 TANK HEATER
Location:
  The tank heater is located inside the tank and 
secured to the tank lid.
Test Procedures:
1.  Disconnect the brewer from the power supply.
2.  With a voltmeter, check the voltage across the 
black and white or red wires. Connect the brewer 
to the power source. The indication must be:
 
a) 120 volts ac for 2-wire 120 volt models.
 
b) 208 volts ac for 3-wire 120/208 volt models.
 
c) 240 volts ac for 3-wire 120/240 volt models.
3.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4
If voltage is not present as described, refer to the 
Wiring Diagram and check wiring harness.
4.   Disconnect the black wire and the white or red 
wire from the tank heater terminals.
5.   Check for continuity across the tank heater termi-
nals.
If continuity is present as described, reconnect the 
wires, the tank heater is operating properly.
P2143.35
If continuity is not present as described, replace the 
tank heater.
NOTE- If the tank heater remains unable to heat, re-
move and inspect heater for cracks in the sheath.
Removal and Replacement:
1.   Disconnect the black wire and the white or red 
wire from the tank heater terminals.
2.  Remove sprayhead and the hex nut securing the 
sprayhead tube to the hood.  Set aside for reas-
sembly.
3.  Disconnect vent tube and water inlet tube.
4.  Remove the eight #8 keps nuts securing the tank 
lid to the tank.
5.   Remove the tank lid with limit thermostat, spray-
head tube, tank heater and vent tube.
6.  Remove the two hex nuts securing the tank heater 
to the tank lid. Remove tank heater with gaskets 
and discard.
7.  Install new tank heater with gaskets on the tank 
lid and secure with two hex nuts.
8.  Install tank lid with limit thermostat, sprayhead 
tube, tank heater and vent tube using eight #8 
keps nuts.
9.  Secure sprayhead tube to hood using a  hex nut.
10.  
Install sprayhead.
11. Connect vent tube and water inlet tube to fitting.
12.   Reconnect the wires to the limit thermostat 
and tank heater. See limit thermostat section in 
this manual when reconnecting wires.
13.   Refer to Fig. 21 when reconnecting the tank 
heater wires. 
FIG. 21 TANK HEATER TERMINALS
P1284.80
BLK to Control Ther-
mostat
WHI to Terminal 
Block (120V)
RED to Terminal 
Block (208&240V)