TROUBLESHOOTING
 
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems 
encountered.  If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic 
Technical Service Department.
•  Inspection, testing, and repair of electrical equipment should be performed only by qualified service person-
nel.
•  All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.
•  Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If
an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a 
terminal or crimp.
•  Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
•  The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will
help to avoid twists and kinks in the tubing.
•  Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
•  This brewer is heated at all times. Keep away from combustibles.
WARNING – 
•  Exercise extreme caution when servicing electrical equipment.
•  Unplug the brewer when servicing, except when electrical tests are specified.
•  Follow recommended service procedures
•  Replace all protective shields or safety notices
Problem
Brew cycle will not start 
Probable Cause
1. No water  
2. No power or incorrect voltage to 
the brewer
3. External Strainer/Flow Control 
(.750 GPM)
4. ON/OFF Switch
5. Start Switch
Remedy
Water lines and valves to the brewer 
must be open.
Check circuit breakers or fuses.
(A) Direction of flow arrow must be 
pointing towards the brewer.
(B) Remove the strainer/flow con-
trol and check for obstructions. 
Clear or replace.
Refer to Service - ON/OFF Switch 
for testing. See page 20 
Refer to Service - Start Switch for 
testing procedures. See page 21
10777 041500