White Rodgers 37E37A-903 & 906 Manual De Usuario

Descargar
Página de 8
3
 
 
 
 
GROUND JOINT UNION
INTELLI-VENT™
CONTROL
GAS SUPPLY 
PIPE
TEE
DRIP LEG
(SEDIMET TRAP)
3" MINIMUM
(MANDATORY)
PIPE CAP
SHUT-OFF VALVE
8.   Open the gas shutoff valve.
9.   
BEFORE TURNING ON THE APPLIANCE, CHECK THE 
GAS LINES FOR LEAKS.
a.  Use a soapy water solution. DO NOT test for gas leaks 
using a match or open flame.
b.  Brush the soapy water solution on all gas pipes, joints, 
and fittings. Use care that excess solution does not 
enter the control’s plastic housing.  
c.  Check for bubbling soap. This means you have a leak.  
Turn OFF the gas and make the necessary repairs.
d.  Turn on the gas and recheck for leaks. Repeat this 
process until you are sure the system is gas-tight. If 
repeated work on a part does not stop the leak, the 
part must be replaced.
e.  Rinse off the soapy solution and wipe all the plumbing 
parts dry.
OPERATING INSTRUCTIONS
1.  The control uses an automatic ignition system to light 
the burner. 
DO NOT TRY TO MANUALLY LIGHT THE 
BURNER.
2.  Wait at least five (5) minutes to clear out any gas, and then 
smell around the appliance area near the floor. If you smell 
gas, 
STOP! Follow the instructions “What to do if you 
smell gas” on the first page of this instructions sheet. If 
you do not detect gas, continue with the next step.
3.  Make sure that both the inner and outer doors are in place. 
These doors are located where the burner tube enters the 
water heater at the bottom. Both doors must be in place for 
safe operation.
4.  Turn on power to the water heater. This can done either 
by turning on the disconnect switch to the water heater, 
or plugging in the water heater to a nearby outlet. The 
installer should have made this provision for you, and 
it must meet local and state ordinances of the National 
Electric Code, whichever applies.
 INSTALLATION
CAUTION
!
Never  use  this  water  heater  unless  it  is  completely 
filled  with  water. To  prevent  damage  to  the  tank,  the 
tank  must  be  filled  with  water. Water  must  flow  from
the  hot  water  faucet  before  turning  ON  gas  to  the 
water heater.
  
Figure 1. Typical gas connection
5.  For a brief (one to five seconds) all of the indicators on 
the front of the control should come on, and then turn 
off. This indicates that the control has completed the 
self-diagnostic test, and is ready for operation. If any 
combination of indicators remain illuminated, either refer 
to the troubleshooting section of this manual, or contact a 
qualified service person.
6.  The water heater is now ready for operation, and will 
begin to heat the water to the factory default setting of 
approximately 70
o
F. If an alternate temperature setting is 
required, please refer to the following section “Temperature 
Regulation.”
TEMPERATURE REGULATION
After the gas and electrical connections are made and the 
water heater tank is full of water, the control will now start to 
heat the water to the factory default setting of approximately 
70°F. If a higher setting is desired, start with the setting at the 
triangle( ). This is approximately the 120°F setting, and the 
safest and most economical setting for the water heater.
To change the temperature setting for either cooler or warmer 
water, the following steps are necessary:
1.  “Wake up” the temperature indicators by pressing the 
COOLER and HOTTER temperature adjustment buttons at 
the same time and releasing after one second (see Figure 
2). One or two of the temperature indicators will light up.  
These indicators will only remain on for 30 seconds if no 
further buttons are pressed. After 30 seconds the control 
will go back to “Sleep” mode, and both buttons will again 
have to be pressed to see the water temperature setting.
2.  If this is the first time that the control has been used, the 
leftmost green indicator will be illuminated indicating the 
water temperature setting of approximately 70°F. See Table 
1 for an explanation of what each of the temperature indi-
cators mean.    
TEMPERATURE
INDICATORS
TEMPERATURE
ADJUSTMENT
BUTTONS
Figure 2. Temperature Indicators and Adjustment
a. 
To decrease the temperature press and release the 
COOLER button once. The temperature indicators will 
now display the new temperature setting. Press and 
release the COOLER button until you have reached the 
desired setting. HOLDING DOWN THE BUTTON WILL 
NOT CONTINUE TO LOWER THE SETTING. The But-
ton must be pressed and released for each tempera-
ture change desired.
b.  
To increase the temperature press and release the 
HOTTER button once. The temperature indicators will 