Brother PS-300B Manual De Propietario
47
BAS-311E.311EL.326E.326EL
Chapter 3. Assembly
12.Press the P key and adjust the X-sensor setting plate
!7 so that the needle !4 is aligned with the home position (X=0,
Y=0) of the H-position standard plate
!1.
13.Press the P key again to make sure that the needle
!4 is aligned with the home position (X=0, Y=0) of the H-position
standard plate
!1.
14.Secure the X-sensor setting plate
!7 using the screw.
15.Remove the needle
!4.
16.Press the P key to be out of the program mode, and turn off the power.
17.Replace the H-position standard plate
17.Replace the H-position standard plate
!1 with the work clamp.
Note: When adjusting the X home position, be sure to set the clearance between the X-home position dog
!8 and the
surface where the sensor is activated to 0.1 - 0.5 mm. If the clearance is too great, an error in home position
detection may occur because the temperature of the sewing machine rises during sewing operation.
detection may occur because the temperature of the sewing machine rises during sewing operation.
0.1 - 0.5mm
H - position
(X=0, Y=0)
(X=0, Y=0)
!1
!4
!7
!8