Sunfire OLE-2SF Manual De Usuario

Descargar
Página de 24
IR
Symptom
Cause
Solution
No control 
of IR 
sources.
1. Programming: 
missing or incorrect 
IR commands.
Verify and correct program-
ming. Test IR commands from 
SunTools.
. Wiring: Incorrect 
wiring between Zone 
and ‘Head-End”.
Verify and correct wiring.
3. Wiring: IR emitter 
connected to wrong 
source IR port of 
multi-room controller.
Verify port connection and 
correct.
IR emitter defective.
Replace IR emitter.
Intermit-
tent source 
control.
IR flooding.
Check to see if any ambi-
ent light is shining on built in 
IR receiver or in direct line 
with plasma TV noise. If the 
Olé-SF cannot be relocated, 
disable the IR receiver in 
SunTools setup software and 
use a plasma friendly external 
receiver as shown on page 14 
of this manual. If installed in 
conjunction with an 3rd-party 
multi-room controller, please 
refer to its own troubleshooting 
steps.