Extension cords
1. 
Grounded tools require a three wire extension cord.  
Double Insulated tools can use either 
a two or three wire extension cord.
2.  As the distance from the supply outlet increases, 
you must use a heavier gauge extension cord.  
Using extension cords with inadequately sized wire 
causes a serious drop in voltage, resulting in loss of 
power and possible tool damage.  
(See Table A.)
3.  The smaller the gauge number of the wire, the 
greater the capacity of the cord.  For example, 
a 14 gauge cord can carry a higher current 
than a 16 gauge cord.  
(See Table A.)
4.  When using more than one extension cord 
to make up the total length, make sure 
each cord contains at least the minimum 
wire size required.  
(See Table A.)
5.  If you are using one extension cord for more 
than one tool, add the nameplate
 amperes 
and use the sum to determine the required 
minimum cord size.  
(See Table A.)
6.  If you are using an extension cord outdoors, make 
sure it is marked with the suffix “W-A” (“W” in 
Canada) to indicate it is acceptable for outdoor use.
7.  Make sure the extension cord is properly wired 
and in good electrical condition.  Always replace 
a damaged extension cord or have it repaired 
by a qualified electrician before using it.
8.  Protect the extension cords from sharp objects, 
excessive heat, and damp or wet areas.
TABLE A:  REcOMMENDED MINIMUM WIRE 
GAUGE FOR EXTENSION cORDS* (120/240 VOLT)
NAMEpLATE
AMpERES
(at full load)
EXTENSION cORD 
LENGTH
25´ 50´ 75´ 100´ 150´
0 – 2.0
18
18
18
18
16
2.1 – 3.4
18
18
18
16
14
3.5 – 5.0
18
18
16
14
12
5.1 – 7.0
18
16
14
12
12
7.1 – 12.0
18
14
12
10
-
12.1 – 16.0
14
12
10
-
-
16.1 – 20.0
12
10
-
-
-
* Based on limiting the line voltage drop to five volts at 
150% of the rated amperes.
Symbology
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
V
Volts
~
Alternating Current
A
Amperes
OpM
Oscillations per Minute
n0 xxxx/min.
No Load Revolutions per Minute (RPM)
WARNING marking concerning Risk 
of Eye Injury.  Wear ANSI-approved 
safety goggles with side shields.
Read the manual before 
set-up and/or use.
WARNING marking 
concerning Risk of Fire.  
Do not cover ventilation ducts.
Keep flammable objects away.
WARNING marking concerning 
Risk of Electric Shock.  
Properly connect power cord 
to appropriate outlet.