Jefferson Direct Vent/Natural Vent Gas Heater 
30004177
ST221
vent thru roof
12/99
Storm Collar
Sealant
Upper 
edge of 
flange goes 
under upper 
shingles
Flashing
#7DVSKV 
(A, B, or 
F) Roof 
Support
Use three #5 
sheet metal 
screws at 
each joint
ST221
Fig. 31  Roof support and flashing.
up to the ceiling, then B-vent pipe must be used. Do 
not mix types of B-vent pipe; use components from 
one maker or the another. Follow the vent component 
maker’s instructions exactly. The heater will also accept 
standard or enamelled 7” (150 mm) diameter pipe, 
aroudn the Type B venting, for decorative purposes 
only. (Fig. 32)
NOTE: The restrictor plate supplied with the stove 
is not used for Natural Vent applications.
The Jefferson stove, when installed as a Natural vent 
heater, includes a vent safety switch. (Page 32, Fig. 63)
Operating the stove when it is not connected to a 
properly  installed and maintained venting system, or 
tampering with or disconnecting the vent safety switch, 
can result in carbon monoxide (CO) poisoning and 
possible death.
For U.S. installations: The venting system must 
conform with local codes and/or the current National 
Fuel Gas Code, ANSI Z22.1.
For Canadian installations: The venting system must 
conform to the current CSA B149.1 installation code.
Install the Vent Pipe
Apply a bead of sealant around bottom end of inner 
starter pipe (found in bag with logset) and attach to 
stove. Apply a bead of sealant around top of inner 
starter pipe and install the Z31B00 FSDHAG Draft 
Hood according to Draft Hood instructions. (Fig. 33)
Attach the first section of venting to the draft hood. 
Depending on the length of the individual venting 
sections and the lengths of the decorative pipe (if 
installed), you may need to slip the decorative pipe over 
the venting sections before attaching upper sections 
to lower ones. The sections of decorative pipe should 
be oriented with their seams (if any) toward the wall; 
Decorative 7” 
Pipe
4” B-vent 
Pipe
Draft Hood 
Adapter
CFM outer pipe 
(7FSSK) may be 
used after Draft 
Hood up to the 
ceiling.
ST358
Decorative
pipe around b-vent
4/26/00   djt
ST358
Fig. 32  Decorative 7” pipe may be fitted around the B-vent 
pipe.
sections usually do not need to be fastened at each 
joint, other than slip sections. If the layout includes 
a slip section, this should be the last section of pipe 
visible in the room, at the ceiling. Complete the venting 
according to the vent maker’s instructions.
ST357
attach draft hood
4/26/00   djt
CEMENT
ST357
Fig. 33  Install draft hood adapter.