7-10 
E&M Ports
Model No.
Running Head
PATTRN
The Pattern is the outgoing test pattern to be sent to the selected port by the system. You can 
send a different pattern to each port. The none setting disables the test pattern. The D-mW 
(Digital milliwatt) option sends a 1 kHz tone at 0.0 dBm. The setting of the Rx TLP field 
adjusts the D-mW signal level before sending the signal to the CPE.
SIG CONV
The Signaling Conversion parameter allows you to change the transmit ABCD signaling bits 
from CCITT (E1) to ANSI (T1) standards, and is accessd by selecting B from the taBs option 
at the bottom of the window.
The options are off if ANSI signaling is used and on to convert transmit signaling from ANSI 
to CCITT format according to the Interface Card Conversion Table for E&M signaling. This 
setting also converts receive signaling from CCITT to ANSI. To see the options currently 
deployed on a port, Figure 7-7 shows the default settings for the conversion table. This table 
will be commonly used by all ports to which the this option is set to on.
The C->A column describes conversion done in the downstream direction towards the 
subscriber loop, while the A->C column describes the conversion done in the upstream 
direction, normally towards the T1 interface.
Figure 7-7.Tabs Signal Conversion - Change Mode