Vulcan V SERIES 
 Owner’s Manual 
Canadian Comfort Industries                                     
                                                 
Fan Limit F140
Low Limit L120
A
UTOMATIC 
S
AFETY 
F
EATURES
 
 
 
L120 LOW LIMIT SWITCH 
This limit switch is mounted on the exhaust blower housing and has 2 main functions.  
1.  Should the fire happen to go out, for any reason, this limit switch will shut the stove off when the exhaust 
temperature drops below 120deg F. 
2.  Upon starting the appliance, the AcuTron control board has a 15 minute “Lighting Mode”, if the stove 
exhaust does not reach 120deg F in that 15 minutes the stove will shut off.  As soon as the stove exhaust 
does reach 120deg F, the limit switch opens and the AcuTron enters a 5 minute “Safety Delay” mode.  
 
F140 FAN LIMIT SWITCH 
Your pellet appliance has a convection 
fan control limit switch.  The room air 
fan's (F140) temperature limit snap 
switch automatically sets the fan on high 
when your stove is producing heat faster 
than the fan is carrying it into the room.  
This may occur when the heat control 
lever is set at [3 or 4] and the FAN 
SPEED
 is set to a very low or off setting.  
After the fan runs at this automatic high 
setting a few minutes, it may cycle back 
to its lower setting and may continue to 
cycle between [HIGH] and your selected 
setting.  The circulation (room air) fan 
cycling from high to low is a normal 
condition as well as a safety feature of 
your appliance. To compensate for the 
fan cycling, adjust the FAN SPEED to a 
higher setting.
  
 
L250 HIGH LIMIT SWITCH 
Your pellet appliance has a high temperature limit switch installed.  If the temperature at the back of the firebox 
reaches approximately 250deg F., the switch will shut off the electricity going to the Vacuum Switch and to the 
Auger Motor.  The auger will automatically stop, and the appliance will shut down when the exhaust temperature 
cools (120deg F).  If this happens call your dealer or Dansons Customer Service (1-866-456-9269).  
 IT IS IMPORTANT TO FIND THE REASON WHY THE UNIT OVERHEATED
 
VACUUM SWITCH 
This safety device (mounted on the back panel pillar) detects vacuum in the exhaust system, firebox, and air intake.  
If the exhaust blower fails, the vent pipe becomes plugged, the viewing door is open, or if you are out of pellets, this 
switch will sense that there is a lack of vacuum and will stop the auger from continuing to feed pellets. 
 
If the power does go out, the pellet appliance will stop running.  When the power comes back on, 
the stove will not restart if the switch is in the manual mode.   If the exhaust temperature is above 
120deg F or the switch is in the manual position, the stove will start to feed pellets again and may 
re-light itself. 
 
NOTE:  If power outages are a concern you may wish to purchase a back-up generator system.    
 
For further information contact your local Specialty Retailer, Certified HVAC Service Depot, or Dansons 
Group Inc. Customer Service Department at 1-866-456-9269.