LOWER “HALL EFFECT” SENSOR (OPTIONAL) 
 
Some L60 tamp label applicators are equipped with two sensors that are attached to 
the air cylinder.  One is located at the top of the cylinder and the other is located 
below it. The upper sensor sends a signal to the machine so another label will be 
dispensed onto the vacuum head.  The lower sensor can be adjusted to control or 
limit the stroke of the air cylinder that returns the vacuum head to the home position.  
The lower sensor is the only one that may require adjustment.   
 
Adjusting the Lower “Hall Effect” Sensor: 
 
1.  With Main switch “On” and Motor switch “Off”. 
2.  Disconnect air supply or turn tamp regulator “Off”. 
3.  Bring Tamp Head down to new product height. 
4.  Loosen Phillips screw on Hall Effect Sensor. 
5.  Slide sensor to top of cylinder, then down until the indicator light on the sensor 
lights up. 
6.  Tighten the Phillips screw on the sensor. 
Hall effect 
sensors. 
Hall effect 
connections. 
Fig 10 
Fig 11