System 
Symptom 
Condition / Workaround 
Issue 
The MO/M1 status LED does not indicate the 
presence of a module. 
Occurs when inserting a module into the 
appliance and booting the system. The M0/M1 
status LED should be on when a valid module is 
detected in the slot and blink if a module is 
present but not supported. 
107620 
The system preferences do not import correctly. 
The LAN IP address is changed to 
192.168.168.168 and the user cannot log in. 
Occurs when importing preferences from a  
TZ 200 appliance into a NSA 250M appliance, 
then performing a restarting. 
107209 
Visualization 
Symptom 
Condition / Workaround 
Issue 
The NetFlow EndTime timestamp results in 
0.00000 for valid and allowed TCP packets.  
 
 
Occurs when the NetFlow collector’s logging is 
enabled on Applicable Interfaces and Rules, and 
TCP traffic is sent to the allowed destination.  Upon 
checking the packet capture details, the EndTime 
timestamp displays as 0.00000. 
102961 
VPN 
Symptom 
Condition / Workaround 
Issue 
Sometimes, the secondary IPSec gateway is 
unable to establish a tunnel with a peer if the 
primary gateway is unreachable. 
Occurs when there are two SonicWALL devices 
with VPN configured and the cable from the 
secondary gateway is unplugged. 
103935 
Having multiple tunnel interface policies with the 
same IPSec gateway but different ports 
configured on the firewall can cause only one 
tunnel to be active. 
Occurs when there are two or more tunnel 
interface policies using the same IPSec gateway 
and those interfaces are bound to different ports. 
103398