Siemens G85139 Manual De Usuario

Descargar
Página de 42
8.
  
SUPPLEMENTARY INFORMATION
English
© Siemens plc 1997
G85139-H1750-U049-B
39
26/09/97
Class 2:  Filtered Industrial
This level of performance will allow the manufacturer/assembler to self-certify their apparatus for  compliance
with the EMC directive for the industrial environment as regards the EMC performance characteristics of the
power drive system. Performance limits are as specified in the Generic Industrial Emissions and Immunity
standards EN 50081-2 and EN 50082-2.
EMC Phenomenon
Standard
Level
Emissions:
Radiated Emissions
EN 55011
Level A1
Conducted Emissions
EN 55011
Level A1
Immunity:
Supply Voltage Distortion
IEC 1000-2-4 (1993)
Voltage Fluctuations, Dips, Unbalance,
Frequency Variations
IEC 1000-2-1
Magnetic Fields
EN 61000-4-8
50 Hz, 30 A/m
Electrostatic Discharge
EN 61000-4-2
8 kV air discharge
Burst Interference
EN 61000-4-4
2 kV power cables, 2 kV control
Radio Frequency Electromagnetic Field,
amplitude modulated
ENV 50 140
80-1000 MHz, 10 V/m, 80% AM,
power and signal lines
Radio-frequency Electromagnetic Field,
pulse modulated
ENV 50 204
900 MHz, 10 V/m 50% duty cycle,
200 Hz repetition rate
Class 3:  Filtered -  for residential, commercial and light industry
This level of performance will allow the manufacturer / assembler to self-certify compliance of their apparatus
with the EMC directive for the residential, commercial and light industrial environment as regards the EMC
performance characteristics of the power drive system. Performance limits are as specified in the generic
emission and immunity standards EN 50081-1 and EN 50082-1.
EMC Phenomenon
Standard
Level
Emissions:
Radiated Emissions
EN 55022
Level B1
Conducted Emissions
EN 55022
Level B1
Immunity:
Electrostatic Discharge
EN 61000-4-2
8 kV air discharge
Burst Interference
EN 61000-4-4
1 kV power cables, 0.5 kV control
Note:
The MICROMASTERS are intended exclusively for professional applications. Therefore, they do
not fall within the scope of the harmonics emissions specification EN 61000-3-2.