SITRANS LC 500 – INSTRUCTION MANUAL 
Page 5
mm
mmm
Spec
ificat
ions
Safety
• current signalling according to NAMUR NE 43; 
3.6 to 22 mA / 22 to 3.6 mA
• probe input ESD protected to 55 kV
• inputs/outputs fully galvanically isolated
• polarity-insensitive current loop
• fully potted
• integrated safety barrier
Diagnostics (Includes 
• primary variable (PV) out of limits
fault alarm)
• system failure measurement circuit
• deviation between A/D and D/A converter 
values
• check  sum
• watch  dog
• self-checking facility
Outputs 
• galvanically isolated
• damping
range 1 to 10,000
Current loop
• continuous signal
4 to 20 mA / 20 to 4 mA 
• 2-state functionality 4 or 20 mA / 20 or 4 mA, on or off 
• time delay
1 to 100 sec. activating / de-activating
• adjustable hysteresis (on / off)  0 to 100%, min. 1% of range
Solid-state switch
40 Vdc / 28 Vac / 100 mA at 2 VA max.
• time delay
1 to 100 sec. activating / de-activating
• adjustable hysteresis (on / off)  0 to 100%, min. 1% of range
User Interface
Local digital display
4 1/2 digit LCD
Rotary function switch
for selecting programmable menu items
• 16 Positions 
0 to 9, A to F 
Push-buttons: RED (+), BLUE (–)
used in conjunction with rotary switch, for 
programming menu items
Communications
HART
 1
 Communication protocol
1.