Protocol description
After power-on, the 
PE
 signal goes to zero. The 
SELECT
 signal and the 
FAULT
 signal 
become one. 
Timing
The host sets the data lines (
DATA 1
  - 
DATA 8
) according to the character to be transferred. 
After a timeout of 0.5 microseconds the host sends a 
STROBE
 pulse with a length of at least 
0.5 microseconds. The character is stored in the printer buffer and the printer sends a 
BUSY
 
signal to the host. When the data byte is stored completely in the printer buffer, the printer 
sends a 
BUSY
 and an 
ACKN
 signal to the host. 
The 
ACKN
 signal informs the host that a data byte has been received and that the printer is 
ready to receive another character. 
When the printer buffer is full, the 
BUSY
 signal is not reset to stop the data stream from the 
host. The 
BUSY
 signal is reset only when at least 256 bytes are free in the printer buffer. 
When the Stop button is pressed, the 
BUSY
 signal remains one and the 
ACKN 
signal is not 
sent. 
If at least 256 bytes are free in the printer buffer, pressing the Start button causes the 
BUSY
 
signal to be reset and an 
ACKN
 signal to be sent to the host.