4.2 INSTALLATION 
4.2.1  Setting the Working Voltage Range Of the Instation Test Set 
The power supply for the modem PCB and Instation Test Set Logic PCB is the 
same type as used on the Instation PSU PCB. Refer to section 2.2.4.1 for a 
description of how to set the voltage range of this power supply. 
 
Note.  The voltage range of the PC used in the Instation Test Set should be 
checked in the manufacturer's literature and note should be taken of any 
links/switches that need setting for different voltage ranges. 
 
4.2.2  TC12 Instation Test Set Software Installation 
The Instation Test Set software is installed by Engineering at Poole before the 
Test Set is shipped.  
 
The software set up on the Instation Test Set PC should not be changed. If there 
are operational reasons for changing the software set up, the UTC Software 
Support Desk (01202 782440 or 
utcsupport@poole.siemens.co.uk
) should be 
consulted before making any changes. 
 
4.2.3  Error Messages during Test Set Software Start Up 
During start up the test set software checks that it can access all the items that it 
needs. If any errors occur a message will be displayed which indicates the cause 
of the error. 
 
If the test set cannot access either of the two necessary serial ports, an error 
message will be displayed in which the status number has the following 
significance: 
 
Serial Port Errors 
-2 
Invalid Port    
 
 
 
Contact engineering at Poole 
-4 
Invalid Buffer Size   
 
 
Contact engineering at Poole 
-5 No 
Memory 
    Contact 
engineering 
at 
Poole 
-6 
Port Not Set Up Correctly   
 
Contact engineering at Poole 
 
-3 
Port Is Already In Use 
 
 
Re-boot PC 
 
-14 
Port Required Could Not Be Found 
Ensure machine is configured for 
 
       two 
serial 
ports; 
COM1 
and 
COM2 
 
System faults 
If the software fails to complete start up with the PC with error message "Internal 
Stack Overflow". This can indicate that the hardware connected to the parallel port 
is not powered correctly, i.e. the test set logic PCB. 
 
666/HE/43100/000  
Page 137 
Issue 9