Siemens TRAFFIC CONTROLS TC12 Manual De Usuario

Descargar
Página de 201
 
TC12 Installation, Commissioning & Maintenance Handbook 
The cover must ALWAYS be fitted before any cables are installed, and should 
NEVER be removed whilst the telephone cable (from socket SK1 on the PCB) is 
connected to the telephone network. 
 
Figure 34 - Integral OTU PCB Layout and Switch Settings 
PLA
S2
PLB
Serial
 No.
Battery
ON/OFF
LP2 - Carrier Detect
LP3 - Transmit confirm
LP4 - Watchdog Fail
SK2 - Reply
Line Jack
Sockets
SK3 - Control
6-Way Telecom Socket
S1
2/4 Wire
Selector
B1
Status
LEDs
S3
Line level
switches
60-Way
connector for
LMU inputs
40-Way
extended
system bus
connector
Lithium Battery
SK1
600R / HI-Z
Selector
S4
Covered area. (Cover same shape on bottom of PCB)
Cover fixing
Processor
PLD
Firmware
Closed ‘1’
when pushed
up. Open ‘0’
when pushed
down.
(Example
shown open)
2 wire
4 wire
600R
HI-Z
On     Off
 
6.3.2.3  Configuring the Switches on the Integral OTU PCB 
Before any connectors are attached to the Integral OTU PCB, the configuration 
switches need to be set up as described below. Figure 34 shows the position of 
the switches on the PCB and the directions to set the switches to for different 
options. 
 
There are four switches on the PCB: 
 
S1 
 
2/4 Wire Select Switch 
S2 
 
Lithium Battery On/Off Switch 
S3  
 
Line Level Switch 
S4 
 
600 Ohm/High Impedance Switch 
 
These are set as follows: 
 
1.  
 
S1 - 2/4 Wire Select Switch 
Set to either 2 or 4 wire (see Figure 34) as required by the position indicated on 
the installation sheet for the Integral OTU. 
 
666/HE/43100/000  
Page 168 
Issue 9