Functions available:
0
Control Bit 0 (Bit 0 of Word 0)
1
Control Bit 1 (Bit 1 of Word 0)
..
..........................
23
Control Bit 23 (Bit 7 of Word 2)
24 - 97
Not used
98
Any lamp failure in any group
99
Any Red Lamp failure in any group
100
Any lamp failure in group 0
101
1st Red Lamp failure in group 0
102
2nd Red Lamp failure in group 0
110
Any lamp failure in group 1
111
1st Red Lamp failure in group 1
112
2nd Red Lamp failure in group 1
..
.. .. .. .. .. .. .. ..
170
Any lamp failure in group 7
171
1st Red Lamp failure in group 7
172
2nd Red Lamp failure in group 7
255
No
function.
Note: Functions 103 - 109, 113 - 119 etc and 173 to 254 are not used.
6.4.2.2 Fault Flags/Data associated with Integral OTU
Fault Flag 58 - Fault with the Integral OTU and/or the facility (FLD 81)
Fault Data 81
Fault Data 81
This single fault data byte indicates the problem with the integral OTU
facility or the integral OTU itself.
facility or the integral OTU itself.
Bit 0: Automatically set when the integral OTU has any fault in its fault
log, use the OTU commands 'GLF' and 'KLF' to examine the OTU
fault log.
fault log.
Bit 1: The Integral OTU has appeared to have failed or is not connected.
RFL=1 will clear this fault if the OTU is now running, i.e. it failed for
just a short time.
just a short time.
The following faults cannot be cleared by RFL=1 alone, most require the
OTU facility to be reset by either:
OTU facility to be reset by either:
Changing the value of the OTU fitted flag - OTF command,
666/HE/43100/000
Page 180