TC12 Installation, Commissioning & Maintenance Handbook 
Functions available: 
 
 
Control Bit 0 (Bit 0 of Word 0) 
 
Control Bit 1 (Bit 1 of Word 0) 
..  
.......................... 
23 
 
Control Bit 23 (Bit 7 of Word 2) 
 
24 - 97  
Not used 
 
98 
 
Any lamp failure in any group 
99 
 
Any Red Lamp failure in any group 
 
100   
Any lamp failure in group 0 
101   
1st Red Lamp failure in group 0 
102   
2nd Red Lamp failure in group 0 
 
110   
Any lamp failure in group 1 
111   
1st Red Lamp failure in group 1  
112   
2nd Red Lamp failure in group 1 
 
..   
 
..   ..  ..  ..  ..  ..  ..  .. 
 
170   
Any lamp failure in group 7 
171   
1st Red Lamp failure in group 7  
172   
2nd Red Lamp failure in group 7 
 
255  
No 
function. 
 
Note:  Functions 103 - 109, 113 - 119 etc and 173 to 254 are not used. 
 
6.4.2.2  Fault Flags/Data associated with Integral OTU 
Fault Flag 58 - Fault with the Integral OTU and/or the facility (FLD 81) 
 
Fault Data 81 
 
This single fault data byte indicates the problem with the integral OTU 
facility or the integral OTU itself. 
 
Bit 0:  Automatically set when the integral OTU has any fault in its fault 
log, use the OTU commands 'GLF' and 'KLF' to examine the OTU 
fault log. 
 
Bit 1:  The Integral OTU has appeared to have failed or is not connected. 
RFL=1 will clear this fault if the OTU is now running, i.e. it failed for 
just a short time. 
 
The following faults cannot be cleared by RFL=1 alone, most require the 
OTU facility to be reset by either: 
 
 
Changing the value of the OTU fitted flag - OTF command, 
666/HE/43100/000  
Page 180 
Issue 9