TC12 Installation, Commissioning & Maintenance Handbook 
2.4.8.15  Received Characters IMD, Key to Press 'R' 
This screen displays the data received from OTUs on IMD 0 port 0. It displays 
each OTUs reply on a separate line on t
shows the OTUs on IMD 0 port 0 but can be used to obtain indication of the health 
of the system. 
 
The characters on each line are the hexadecimal representation of the reply bytes 
(__ means no data) for that OTU, each line is the correct length (number of 
characters) for the number of reply bytes for the OTU. 
 
2.4.8.16  Test Characters, Key to Press 'T' 
Displays a set of characters to test the modes of the display. Not of any real use in 
maintenance of the Instation, as in normal use the Instation has no display. 
 
2.4.8.17  Reset Free time counters and IMD status indicators, Key to Press 'Z' 
Simply resets counters to best condition i.e. 100% free, and IMD cumulative status 
indicators to 0. 
 
2.4.8.18 Exit 
This text shows the combination of keys to press to exit the TC12 software on the 
PC and return to DOS. 
 
2.4.9 Fuses 
ternal Power Supply Fuse on the PSU PCBs 
The Power supply fitted to every PSU board used in the system (part number 
nufactured by Daren Electronics PLC type PP40-30) is fitted 
Figure 16 shows the layout of the Master Switch Panel and RCD. The positions of 
re shown. 
666/HE/43100/000  
Page 59 