6.5.7  Menu item Setup (firmware version - steam)
Level
Designation
Selection / entry
Explanation
3.1
Set display
3.1.1
Error Msg.
Display error
Yes    ↑...
Shows error messages in measuring mode in plain text 
alternating with the measured values
No    ↑...^
Flashing cursor in the top left corner of the display 
indicates errors.
3.1.2
Cycle.Disp.
Display measured values
Yes    ↑...
Cyclically display measured values in measuring mode
(6 s intervals)
No    ↑...^
Do not display measured values cyclically
3.1.3
Code 1
Set security query 1 (menu)
Yes    ↑...
Activate access code:
→→→↑↑↑^^^
No    ↑...^
Deactivate access code
3.2
I/O settings
3.2.1
4-20mA off
Current output 4-20 mA and error current
4-20mA    ↑...
Current output 4-20 mA
4-20/22E    ↑...  
Current output 4-20 mA or error current 22 mA
4-20/3.55E    ↑...^
Current output 4-20 mA or error current 3.55 mA
3.2.2
Variable I
(available if Meter Type = 
Gross Heat, see menu 
item 5.4.1, service menu)
Set output variable for current output
Maes.Inst ↑...
Flow rate
Power ↑...^
Power
3.2.3
Power Unit
(available if Meter Type = 
Gross Heat, see menu 
item 5.4.1, service menu)
Set unit for heat output
kJ/h
Unit    ↑...^
Select unit for measuring heat output
Disp. on /
Disp. off   ↑...^
Display measured value/
Do not display measured value
3.2.4
FS power
(available if Variable I = 
Power, see menu item 
3.2.2)
End value for power measuring range
7000000.00
kJ/h ^
Power value at 20 mA current output
3.2.5
Function P
Function P
Yes    ↑...
Activate pulse output
No    ↑...^
Deactivate pulse output
3.2.6
Variable P
(available if Meter Type = 
Gross Heat, see menu 
item 5.4.1, service menu)
Set output variable for the pulse output
Total Flow ↑...
Total flow
Energy ↑...^
Energy
3.2.7
Totalizer
Totalizer
Tot. on    ↑...
Start totalizer
Tot. off    ↑...^
Stop totalizer (value is held)
3.2.8
Tot. Conf.
Configure totalizer
MA_Siemens_Sitrans_FX300_R02_en_PRT.book  Page 54  Monday, June 22, 2009  8:17 AM