TC63 AT Command Set  
13.5 AT+CMGL
s
TC63_ATC_V00.490
Page 328 of 501
5/24/05
Confidential / Draft - Do not copy
 
Notes
• The selected 
 can contain different types of SMs (e.g. SMS-DELIVERs, SMS-SUBMITs, SMS-STA-
TUS-REPORTs and SMS-COMMANDs), the response may be a mix of the responses of different SM types.
TE application can recognize the response format by examining the third response parameter. 
• The parameters 
 will only be displayed if parameter 
 of the 
 command is
set to 1. 
• This command can be used only after the SMS data from the SIM have been read successfully for the first
time. Reading starts after successful SIM authentication has been performed, and may take up to 30 seconds
depending on the SIM used. While the read process is in progress, an attempt to use any of the SMS read
commands will result in ''+CME Error: 14'' (SIM busy) 
• We recommend to take advantage of the "^SSIM READY" URC. If enabled with 
, this URC acknowl-
edges to the user that SIM data is accessible after SIM PIN authentication. It will be delivered once the ME
has completed reading data from the SIM card.