Schneider Electric ALTIVAR 58 TRX Manual De Usuario

Descargar
Página de 232
Altivar
®
 
58 TRX AC Drives
Selection
©
 2000–2003 Schneider Electric All Rights Reserved
128
09/2003
Available Type H Models (Continued)
Input Line 
Voltage
3-Phase Motor Power (HP)
Continuous Output Current (A)
Catalog No. 
without Keypad
CT
CTLN
VT
VTLN
CT
CTLN
VT
VTLN
400/460 Vac 
3-Phase
1
1
1
2.3
2.1
2.1
ATV58HU18N4ZU
2
2
2
4.1
3.4
3.4
ATV58HU29N4ZU
3
3
3
5.8
4.8
4.8
ATV58HU41N4ZU
5
7.8
6.2
7.6
ATV58HU54N4XZU
5
5
*
7.5
10.5
7.6
*
11
ATV58HU72N4XZU
7.5
7.5
*
10
13
11
*
14
ATV58HU90N4XZU
10
10
*
15
17.6
14
*
21
ATV58HD12N4XZU
15
15
*
20
24.2
21
*
27
ATV58HD16N4XZU
20
20
*
25
33
27
*
34
ATV58HD23N4XZU
25
20
25/30
25
40.7
33
34/40
34
ATV58HD28N4XZU
30
25
40
30
48.4
40.7
52
40
ATV58HD33N4XZU
40
30
50
40
66
48.4
65
52
ATV58HD46N4XZU
50
40
60
50
79.2
66
77
65
ATV58HD54N4XZU
60
50
75
60
93.5
79.2
96
77
ATV58HD64N4XZU
75
60
100
75
115.5
93.5
124
96
ATV58HD79N4XZU
...
...
125
...
...
...
156
...
ATV58HC10N4XZU
...
...
150
...
...
...
180
...
ATV58HC13N4XZU
...
...
200
...
...
...
240
...
ATV58HC15N4XZU
...
...
250
...
...
...
302
...
ATV58HC19N4XZU
...
...
300
...
...
...
361
...
ATV58HC23N4XZU
...
...
350
...
...
...
414
...
ATV58HC25N4XZU
...
...
400
...
...
...
477
...
ATV58HC28N4XZU
...
...
450
...
...
...
515
...
ATV58HC31N4XZU
...
...
500
...
...
...
590
...
ATV58HC33N4XZU
Abbreviations: CT = constant torque CTLN = constant torque, low noise; VT = variable torque; VTLN = variable torque, low noise.
If an EMC filter to meet level A compliance is desired, delete the X from the catalog number.
*
These ratings encompass all 400/460 Vac applications with or without an EMC filter. For 460 Vac applications without an EMC filter, these ratings 
would be the same as the ratings in the VTLN columns.
These products, without EMC filters, are for 460 Vac applications and can be used at the motor power and output current ratings provided in the 
VTLN columns. For 400 Vac applications, or if an EMC filter is required, delete the X from the catalog number and use the motor power and output 
current ratings provided in the CT and VT columns. Do not use the VTLN ratings denoted with the 
 symbol.