3. Installation
RuggedCom® RuggedBackbone™
21
RX1512 Installation Guide Rev 105
3.2.3. DC Power Supply Wiring Example
+
Figure 3.9. Wiring for RX1512 DC Power Supply
• It is recommended to provide a separate circuit breaker for the power supply.
• Equipment must be installed according to applicable local wiring codes.
3.3. Critical Alarm Wiring
The  Critical  Alarm  output  relay  signals  critical  error  conditions  that  may  occur  on  the
RuggedBackbone™ RX1512. The contacts are energized upon power-up of the unit and remain
energized unless a critical alarm condition is detected. Relay connections are shown in the 
 diagram. You can configure control of the relay output through the ROX™
user interface.
A common application for this output is to signal an alarm in case of a power failure.
Figure 3.10. Critical Alarm Relay Connector