Service Manual
Third edition, June 1997
3.10
Level Unit – Temperature Data
The Temperature Data-window shows the dynamic data and
the database values for the temperature measurement.
Select a new tank by hitting the Tank-button or by hitting the
up or down arrow keys.
The dynamic data box shows:
Int temp
. The internal temperature measured by a
sensor inside the Transmitter is displayed.
Temp avg
. The average temperature calculated as the
average of the values from the sensors that are im-
mersed in the liquid.
Temp 1, 2 or 3
. The value from each individual sensor is
displayed.
The following status are shown:
Note:
 Temperature sensor number 1 is the lowest sensor. If only
two sensors are used, these will be number 1 and 2, with number 1
as the lowest.
TX comfail
 indicates that the transmitter is not commu-
nicating. This produces an alarm on the alarm row.
Int temp fail
. The internal temperature measurement
has failed when the box is checked.
Avg error
. This box is checked if it was not possible to
calculate any average temperature. For example if there
is no temperature sensor in the liquid.
Temp 1, 2 or 3 fail.
 This temperature sensor does not
produce an acceptable value.
Int Temp valid
. This box is checked when the internal
temperature sensor is producing an acceptable value.