Royal Appliance Air Furnace Manual De Usuario
29733 R2 06/01/2003
18
TABLE A-1 BECKETT AFG OIL BURNER SET-UP
BECKETT AFG SERIES OIL BURNERS
FURNACE
MODEL
OUTPUT
BTU/Hr
BURNER
MODEL
NOZZLE
PUMP
PRESSURE
FLOW
RATE
HEAD
STATIC
PLATE
80F (060)
58,100
1, 2
AF76BO
0.50 / 70° W
100 PSIG
0.50 GPH
F0
3-3/8 in.
80F (070)
68,000
2
AF76BN
0.65 / 70° W
100 PSIG
0.65 GPH
F3
3-3/8 in.
80F (080)
78,900
2
AF76BN
0.70 / 70° W
100 PSIG
0.70 GPH
F3
3-3/8 in.
120F (090)
87,700
2
AF76BZHS
0.75 / 70° W
100 PSIG
0.75 GPH
F4
3-3/8 in.
120F (100)
98,800
AF76BZHS
0.85 / 70° W
100 PSIG
0.85 GPH
F4
3-3/8 in.
120F (120)
113,400
AF76BZHS
1.00 / 70° W
100 PSIG
1.00 GPH
F4
3-3/8 in.
1
F0 Head required for proper combustion.
2
Low Firing Rate Baffle required, Beckett Part No. 3708
In the United States, the R. W. Beckett “AFG” Burner may be equipped with Beckett’s “Inlet Air Shut-Off”, Beckett Part No. AF/A 5861, to increase efficiency. It
reduces the amount of air passing through the oil burner, combustion chamber, breeching, etc. up the chimney between burner cycles.
NOTE: THE USE OF THIS CONTROL CAN OCCASIONALLY CAUSE POST COMBUSTION NOZZLE DRIP.
reduces the amount of air passing through the oil burner, combustion chamber, breeching, etc. up the chimney between burner cycles.
NOTE: THE USE OF THIS CONTROL CAN OCCASIONALLY CAUSE POST COMBUSTION NOZZLE DRIP.
TABLE A-2 RIELLO 40F OIL BURNER SET-UP
RIELLO 40 F SERIES OIL BURNERS
FURNACE
MODEL
OUTPUT
BTU/Hr
BURNER
MODEL
NOZZLE
PUMP
PRESSURE
FLOW
RATE
HEAD
STATIC
PLATE
80F (060)
58,000
40 F3
0.40 / 60° W
160 PSIG
0.50 GPH
1.5
2.25
80F (070)
73,000
40 F3
0.50 / 60° W
150 PSIG
0.60 GPH
1.5
2.5
80F (080)
79,000
40 F3
0.60 / 60° W
145 PSIG
0.70 GPH
2.0
3.0
120F (090)
87,000
40 F3
0.75 / 70° W
150 PSIG
0.75 GPH
2.0
3.52
120F (100)
100,000
40 F3
0.85 / 70° W
150 PSIG
0.85 GPH
2.5
4.0
120F (120)
118,000
40 F3
1.00 / 70° W
160 PSIG
0.95 GPH
3.0
6.0
Appendix A