Ridgid RD80763 Manuales De Servicio

Descargar
Página de 28
11
ASSEMBLY
iNlet 
coUpler
high 
pressUre hose
collAr
 
wARNING:
Make  sure  the  nozzle  and  hose  connections  are   
secure before starting the machine. A non-secured 
accessory could become a projectile if not properly 
installed which could result in serious injury. 
ASSEMBLING THE TRIGGER HANDLE
See Figure 7.
  Place 
the threaded end of the spray wand in the connec-
tor on the end of the trigger handle.
  Turn the connector clockwise until it stops. This 
secures 
the wand in place.
  When not in use, remove the spray wand from the trigger 
handle by turning the connector counterclockwise. 
Store 
the unassembled spray wand in the spray wand sto
rage 
area.
ATTACHING THE AUXILIARY HANDLE
See Figure 7.
  Place the threaded stud on the end of the auxiliary handle 
into the hole in the trigger handle as shown below. Turn 
clockwise to tighten. 
 
NOTE: You can install the handle on either the left or right 
side of the spray wand, depending on operator prefer-
ence. The handle must always be used to prevent loss 
of control and possible serious injury.
  To switch sides, loosen the auxiliary handle and rotate to 
the opposite side. Tighten securely before use.
CONNECTING  HIGH  PRESSURE  HOSE  TO  
TRIGGER HANDLE
See
 Figure 8.
  Pull back and hold the collar on the high pressure hose. In-
sert the inlet coupler on the trigger handle into the collar.
  Release the collar and push until it locks into place. Pull 
on the hose to be certain it is properly secured.
ATTACHING INJECTION HOSE
See Figure 9.
Before detergent can be used with this machine, the injection 
hose must be attached.
  Push the open end of the clear injection hose securely 
over the fitting as shown in 
figure 9.
  Place the filtered end of the injection hose in the bottle 
of detergent.
Fig. 7
AUxiliArY 
hANdle
sprAY 
wANd
trigger 
hANdle
coNNector
Fig. 8
iNjectioN hose
Fig. 9