RGB Spectrum Quadra Manual De Usuario
C O M M A N D L I N E I N T E R F A C E
Command Summary
350-7951
Quadra User’s Guide
59
.
. .
.
.
I N P U T C O M M A N D S D E S C R I P T I O N S
The table below lists all input commands, their arguments and detailed
descriptions.
descriptions.
Table 4-3.
Input Commands Descriptions
Command
Arguments
Description
INputAutoSync
<input # | ALL> [ON | OFF
| DEBUG]
| DEBUG]
Sets the input mode for the specified input.
ON
enables the autosync circuitry.
OFF
disables the
autosync circuitry.
When Autosync is enabled (
ON
), the current WSR
settings are automatically reset to full size when the
input signal is re-synchronized.
input signal is re-synchronized.
When Autosync is disabled (
OFF
), the WSR
settings are retained even with a loss of the input
signal.
signal.
Debug
provides information on input status and
reports changes to measured parameters.
Default:
ON
INputFormat
<input #>
Checks the video format of the current video input
selection. The command is only valid when
selection. The command is only valid when
The response to the command will be NTSC or
PAL.
PAL.
INputINTeractive
<input#>
Enters input interactive mode to visually adjust
specified input’s timing parameters. A white box
appears over the full screen input.
specified input’s timing parameters. A white box
appears over the full screen input.
Starting with the upper-left corner of the image, use
these keyboard controls to position the image within
your display raster:
these keyboard controls to position the image within
your display raster:
i
= move up
j
= move left
m
= move down
l
= move right
With the upper-left corner properly adjusted,
address the lower-right corner next by using these
keyboard controls:
address the lower-right corner next by using these
keyboard controls:
I
= move up
J
= move left
M
= move down
L
= move right
With the image properly adjusted, quit the utility:
q
= quit
After you have adjusted the input to your
satisfaction, use the
satisfaction, use the
command to
name your input source, and the
command to store the setting to the Input List.