External cables are attached to connectors on the rear panel of the CDM-600. These
comprise:
Name
Ref Des
Connector Type
Function
Rx IF
J1
BNC
RF Input
Tx IF
J2
BNC
RF Output
Aux Serial
P6
He1402 3 pin header
Auxiliary Serial
Overhead
P3A
25-pin D (male)
Overhead Data
Data Interface
P3B
25-pin D (female) Data
Input/Output
External Reference
J9
BNC
Input
Audio
P4A
9-pin D (female) Sound
Input
Remote Control
P4B
9-pin D (male)
Remote Interface
IDR Alarm
P5A
15-pin D (female)
Alarm
Alarms
P5B
15-pin D (male)
FORM C Alarm
Balanced G.703
P7
15-pin D (female)
Balanced G.703 Data
IDI
J10A
BNC
Insert Data In
DDO
J11A
BNC
Drop Data Output
Rx Unbalanced
J10B
BNC
Receive G.703
Tx Unbalanced
J11B
BNC
Transmit G.703
External Frequency Ref
J12
SMA
External IF reference
Input (Optional)
Input (Optional)
Note: The European EMC Directive (EN55022, EN50082-1) requires using properly shielded
cables for DATA I/O. These cables must be double-shielded from end-to-end, ensuring a
continuous ground shield.
cables for DATA I/O. These cables must be double-shielded from end-to-end, ensuring a
continuous ground shield.
4.3.1
IEC Line Input Connector
The IEC line input connector contains the ON/OFF switch for the unit. It is also fitted
with two fuses - one each for line and neutral connections (or L1, L2, where appropriate).
These are contained within the body of the connector, behind a small plastic flap.
with two fuses - one each for line and neutral connections (or L1, L2, where appropriate).
These are contained within the body of the connector, behind a small plastic flap.
• For 230 volt AC operation, use T0.75A, (slow-blow) 20mm fuses.
• For 115 volt AC operation, use T1.25A, (slow-blow) 20mm fuses.
IMPORTANT
For continued operator safety, always replace the fuses with the correct
type and rating.
type and rating.