Polycom EF2241 Manual De Usuario

Descargar
Página de 68
T
HE
 EF B
US
© Polycom, Inc.
25
V
ORTEX
 EF2241
 
Reference Manual
EF Bus Reference. 
In a system with multiple devices, if all devices need the 
same echo canceller reference, one device should be designated to put its echo cancel-
ler reference (either Ref 1 or Ref 2) on the EF bus to be used as the EF Bus Reference.  
All other devices
 
may use the EF bus reference as the reference for their echo cancel-
lers, or they can use their own internal references.  The references may include a mix 
of any input, with crosspoint gains, including W, X, Y, and Z busses.
NOM Bus. 
The W, X, Y, and Z busses on the EF Bus contain NOM information.  
See “NOM Active” on page 31 for more information on how NOM attenuation is 
applied.
4. Configure Your 
Echo Canceller 
Reference
Review what inputs need to be included in your echo canceller reference — See 
“Build Your Echo Canceller Reference” on page 17.  Remember that each micro-
phone needs to have an echo canceller reference.  If all microphones are in the same 
room and use the same reference, configure the echo canceller reference on one Vor-
tex device  and assign it to the EF Bus as the EF Bus Reference.  Only one Vortex 
device out of multiple units linked together can put an echo canceller reference on the 
EF Bus.  For each additional unit, assign the echo canceller reference to use the EF 
Bus Reference.
For systems with more than one room, you will need to use the W, X, Y, or Z sub-
busses to share the echo canceller reference in your additional rooms if the EF Bus 
Reference has already been assigned to the EF Bus.
P
RESETS
After configuring your Vortex device, save your settings to a User Preset (P
RESETS
 
16-47).  Also, set the P
OWER
 O
N
 P
RESET
 to the User Preset you have saved to.  The 
P
OWER
 O
N
 P
RESET
 determines how the unit is configured upon power up.
If you have multiple Vortex devices in your system, save to a User Preset on each unit 
and set the P
OWER
 O
N
 P
RESET
 accordingly.
O
THER
 EF2241 F
EATURES
For information on Macros, Logic Inputs, Logic Outputs, Input Filters and Output 
Filters, please refer to the Conference Composer User Guide.
Note. 
The EF Bus must be connected so that the EF B
US
 O
UT
 of one 
Vortex device is connected to the EF B
US
 I
N
 of another Vortex 
device.  Connecting EF B
US
 I
N
 to another EF B
US
 I
N
 (or EF B
US
 
O
UT
 to EF B
US
 O
UT
) will not work.  See“Connector Pinouts” 
on page 51 for pinout of Cat 5 cable.