Planet Technology LCD MONITOR 170S8FS Manual De Usuario

Descargar
Página de 26
8
9
Chapter 4 
CONFIGURING THE SYSTEM
This  chapter  provides  network  managers  and  system  administrators  with  information 
about how to configure the WMC-1600R via the Management interface. 
4.1 Configure Through Terminal Emulator/TELNET Program
4.1.1 Console and Terminal Emulator program setting
The WMC-1600R can be accessible using a terminal or terminal emulator attached to the 
RS-232 serial port.
1.Locate correct DB9 serial port cable with female DB9 connector.
2.Attach the DB9 serial port female cable connector to the male DB9 serial port connector 
on the chassis system.
3.Attach the other end of the DB9 serial port cable to a remote the workstation.
4.By default, the Management Module uses the following serial port parameter values:
Bits per second 
57600
Stop bits 
 
1
Data bits 
 
8
Parity 
 
NONE
Flow Control   
NONE
The default Login name and password is both “root".
4.1.2 TELNET program setting
The WMC-1600R can be accessible using TELNET through LAN.
1. Run TELNET program.
2. Enter the IP address "
192.168.1.1
" (the factory-default IP address setting).
3. The default Login name and password is both "root".