10
.04
 Parameter 
settings
Parameter settings are described in the separate operations manual for 
the drive, and may only be changed by qualifi  ed technicians!
 
See Chapter 3 Specifi cations
*
  Adjustment see Chapter 8.05 Basic position of the machine drive unit.
10
.04.01 
Parameter list for PicoDrive with control unit P41 PD2
Group
P
arameter
Description
User lever
S
et
ting range
S
et value 
1
105
Speed for start backtackl
B, C
300 - 2000
1500
110
Speed for end backtack
B, C
300 - 2000
1500
6
606
Speed min
B, C
30 - 300
180
607
Speed max.
B, C
300 - 6000
609
Cutting speed 1
B, C
60 - 300
220
668
Thread wiper/thread blower
1 = on; 0 = off
B, C
0 - 1
0
7
700
Needle position 0 
(needle reference position
B, C
0 -255
*
702
Needle position 1 (needle lowered)
B, C
0 - 255
79
703
Needle position 2 (take-up lever raised) 
B, C
0 - 255
222
705
Needle position 5 (end cutting signal 1)
B, C
0 - 255
175
706
Needle position 5 (start cutting signal 2)
B, C
0 - 255
135
707
Needle position 9 (start thread tension 
release/start thread catcher)
B, C
0 - 255
190
797
Hardwaretest (OFF / ON ),
B, C
OFF
799
Selected machine class
C
1 - 3
1
8
800
Rotating direction of the motor
C
0 - 1
1
802
Main drive reduction ratio
0 = 1:1, 1 = variable
C
0 - 1
0
9
985
Switch on angle for thread trapper
B, C
0 -255
67
986
Switch off angle for thread trapper
B, C
0 -255
206
989
Thread trapper at beginning of seam
0 = no 
1 = yes
2 = Thread clamp with sewing foot lift
B, C
0 - 2
0