BATTERIES 
The P5300 series portable radios use rechargeable, recyclable Nickel Cadmium (NiCd), Nickel Metal 
Hydride (NiMH), or Lithium Ion (Li Ion) batteries. Please follow the directions below to maximize the 
useful life of each type of battery. 
 
 
Do not disassemble or modify Lithium Ion battery packs.  The Lithium Ion battery 
packs are equipped with built-in safety and protection features.  Should these 
features be disabled or tampered with in any way, the battery pack can leak acid, 
overheat, emit smoke, burst, and/or, ignite. 
 
 
If the battery is ruptured or is leaking electrolyte that results in skin or eye contact 
with the electrolyte, immediately flush the affected area with water. If the battery 
electrolyte gets in the eyes, flush with water for 15 minutes and consult a physician 
immediately. 
4.1 
CONDITIONING BATTERY PACKS 
4.1.1 
Conditioning NiMH Battery Packs 
Condition a new NiMH battery before putting into use. This also applies to rechargeable NiMH batteries 
that have been stored for long periods (weeks, months, or longer). Conditioning requires fully charging 
and fully discharging the battery three (3) times using the tri-chemistry charger.  The first time the battery 
is put into the charger, this unit will condition Nickel-based battery packs by automatically charging and 
discharging (cycling) the battery.  Refer to the appropriate charger manual for details. 
CAUTION
 
Failure to properly condition NiMH battery packs before initial use will result in 
shortened performance by the battery. 
4.1.2 
Conditioning NiCD Battery Packs 
A new NiCD battery does not require conditioning before use.  However, M/A-COM recommends 
periodically conditioning NiCD batteries to avoid the memory effect which results when a NiCD battery 
is repeatedly charged and not fully discharged, further resulting in a lower voltage and a lower capacity. 
Fortunately, both nominal voltage and capacity are restored through battery conditioning.   
Conditioning requires fully charging and fully discharging the battery three (3) times using the tri-
chemistry charger.  The first time the battery is put into the charger, this unit will condition Nickel-based 
battery packs by automatically charging and discharging (cycling) the battery.  Refer to the appropriate 
charger manual for details.