Tyco Electronics M/A-Com P5300 Manual De Usuario

Descargar
Página de 104
MM-008212-001, Rev. A 
70 
5.  Press 
 a third time to set the group to Priority 1. A   is displayed on line three. The priority level 
selection sequence only advances the group to next higher priority level and stops at priority level 1. 
To select a lower priority level, the group must be deleted from the scan list and then added back to 
the scan list. Each new group added to the scan list starts at the lowest priority. If the Priority 1 and 
Priority 2 groups are already set and a new group is assigned as Priority 1 or Priority 2, the previously 
assigned group will change to non-priority scanning. One of the following messages may be 
momentarily displayed. 
SCAN DIS  The radio is not programmed to scan.  
FIXED P1  A Priority 1 group has been pre-programmed into the radio. A new Priority 1 group 
cannot be selected.  
FIXD LST  A fixed scan list has been pre-programmed into the radio. It is not possible to change 
the list without reprogramming the radio.  
 
 
To quickly view multiple group scan status, press either 
 or the 
 key. Then slowly 
but consistently rotate the group knob. Each group status will appear on the display. 
9.19.3 
Deleting Groups from a Scan List 
P5350 Model Radio 
1.  With scan operation turned OFF, select the desired group to delete from the selected trunked system 
group scan list.  
2.  Press 
. The current status of the group is displayed for a time-out period.  
3.  While the current status is displayed, press 
. until the group from the scan list is "blank". The 
sequence is "blank",   ,   ,   ,"blank". Any group that is not in a trunked system group scan list will 
show a "blank" for the time-out period when it is the selected channel. 
P5370 Model Radio 
1.  With scan operation turned OFF, select the desired group to delete from the selected trunked system's 
group scan list.  
2.  Press 
. The current status of the group is displayed for a time-out period.  
3.  While the status is displayed, press 
 
to delete the group from the scan list.   ,   ,or   turns OFF. 
Any group that is not in a trunked system group scan list will show a "blank" for the time out period 
when it is the selected channel. 
9.19.4 
Nuisance Delete  
A group can also be deleted from the scan list, if it is not the currently selected group, by pressing the 
 
key (P5350 model) or the 
 key (P5370 model) during scan operation while the radio is displaying the 
unwanted group. The group will be deleted from the system's group scan list in the same manner as if 
done using the steps above. Deletions done in this manner will not remain deleted if the radio is powered 
OFF and then powered ON.