Trilogy Touch Technology Trilogy Commander Digital Intercom 9 Manual De Usuario

Descargar
Página de 81
Commander Installation Guide 
 
 
 
 
 
 
 
 
 
 
 
Trilogy Communications Limited 
Page 43 of 81 
Issue 9 
 
5.7  500-42-50 1U, 10 LEVER KEY PANEL WITH LED DISPLAYS. 
Information about the following legacy panel types is also provided here: 
•  500-44-50 1U, 10 lever key reduced facility control panel without displays. 
• 500-44-51 
 
5.7.1  SPECIFICATION 
 
Dimensions 
485mm wide x 44.5mm high x 150mm deep 
(excluding connectors) 200m approx. (including 
mating connectors) 
19” x 1RU rack mounting 
Mains Input 
90 – 260 V ac, 50-60Hz 
Current Consumption 
150mA @ 90V ac, 50mA @ 250V ac. 
 
5.7.2  REAR CONNECOR LAYOUT 
 
 
5.7.3  CONNECTIONS 
 
Expansion out – RJ-45 fixed socket on 
panel 
RJ-45 
Pin 
Function  
Panel Data in + 
Pair 
Panel Data in - 
Panel Data out + 
Pair 
Panel Data out - 
Panel Audio out + 
Pair 
Panel Audio out - 
Panel Audio in + 
Pair 
Panel Audio in - 
 Cable 
Screen  
 
Matrix – RJ-45 fixed socket on panel 
RJ-45
Pin 
Function  
Panel Data out + 
Pair 
Panel Data out - 
Panel Data In + 
Pair 
Panel Data In - 
Panel Audio out +  Pair 
Panel Audio out - 
Panel Audio in + 
Pair 
Panel Audio in - 
 Cable 
Screen