Trilogy Touch Technology Trilogy Commander Digital Intercom 9 Manual De Usuario

Descargar
Página de 81
Commander Installation Guide 
 
 
 
 
 
 
 
 
 
 
Page 56 of 81 
Trilogy Communications Limited 
Issue 9 
7.2  TELEPHONE INTERFACES 
The Trilogy 500-19 range of equipment provides full DTMF telephone facilities when used in 
conjunction with the Telos ONE “smart” telephone hybrid. To obtain the full facilities 
available with the Commander system, the Telos ONE should be fitted with the Telos Super 
Auto Answer (SAA) option. During the installation it is important to remember that the 
Telephone Interface must be connected to the matrix via a panel port wired with 4 pair cable. 
The connection is not just audio / 4-wire, there is a data exchange between the matrix and 
telephone interface. Each 500-19-10 Rack Mounting Frame can contain a maximum of three 
500-19-00 Telephone Interface Cards. An installation specification for the frame is given 
below.  
Trilogy 500-19-10 Telephone Interface Frame 
Dimensions 
485mm wide x 44.5mm high x 440mm deep 
(excluding connectors) 
19” x 1RU rack mounting 
Mains Input 
90 – 250 V ac, 50-60Hz 
Power Consumption 
45VA 
 
Connector Detail (per channel) 
Active link to matrix 
D9 Fixed Plug 
Audio to Telos Hybrid 
3 pin XLR Fixed Plug 
Audio from Telos Hybrid 
3 pin XLR Fixed Socket 
Control link to Telos Hybrid 
D15 Fixed Plug 
 
Each connection to a telephone line requires a separate Telos ONE hybrid. An installation 
specification is given below. 
Telos ONE Telephone Hybrid 
Dimensions 
485mm wide x 44.5mm high x 240mm deep 
(excluding connectors) 
19” x 1RU rack mounting 
Mains Input 
100 – 240 V ac, 50-60Hz 
Power Consumption 
90mA – 50mA 
 
Connector Detail  
Audio to Trilogy Telephone Interface 
3 pin XLR Fixed Plug 
Audio from Trilogy Telephone Interface 
3 pin XLR Fixed Socket 
Control link to Trilogy Telephone Interface 
15 way D Fixed Socket 
Telephone Line 
RJ-11 
 
If the Telos equipment is purchased separately (i.e. not via Trilogy) it is important to specify 
to your supplier that the equipment is for connection to a Trilogy Commander system. This 
allows the correct software versions and hardware modifications to be fitted.  
A typical system interconnection diagram is given below.