Triax SR-26 Manual De Usuario

Descargar
Página de 22
- 11 -
To skip a program, “PR. SKIP” line is used. If it is enabled, the user can not reach this
program with “P+”, “P-” buttons. Only direct accessing is enabled to watch the skipped
program.
“TV” is used to return without saving, “Store” button to return to the program mode with
saving for selected channel number.
To store the customizing page, ”Store” button is pressed and then program number
begins to flash. “+”,”-” or “0-9” buttons  are used to change channel  number. After
entering the program number ”Store” button is pressed again to save the program
settings to this program.
Installation:
This page depends upon the DiSEqC mode selection in the setup menu. Setup menu
and the other modes of this page will be explained later in “notes to the system in-
staller” part.
While DiSEqC is OFF installation menu seems like this:
In this page, technical specifications for 8 different LNBs are defined. In the “LNB
FREQ.” line, for each LNB, Local Oscillator frequency can be selected by using “+”,
“-” buttons from 8 preset values: 9750, 10000, 10600, 10750, 11000, 11250, 11475
MHz for Ku Band and 5150MHz for C Band.
• In “POL” line, polarity is changed as vertical or horizontal by “+”,”-”.
• “22 kHz” can be switched for each LNB. 22 kHz can be used either for dish switch-
ing (with a 22kHz switch) or Universal LNB frequency band switching. If DiSEqC
is ON in setup menu, 22kHz can only be used for frequency band switching for
universal LNB’s.
• “TONEBURST” signal can be used for each LNB to select dishes with a
toneburst switch.