December 2002 TOSHIBA TEC
1 - 61
e-STUDIO160/200/250 ADJUSTMENT ITEMS
1.4.3  Scanner unit adjustment
a) CCD primary scanning deviation
(1) Place the scale (its end to the rear side original scale and its side to the left side original scale) on the
original glass and make an A4/LT 100% copy.
(2) In order to correct the distance "E", which should be 100 mm from the position copied to the bottom
of the paper, adjust as follows.
Notes: 1. An increase in the value makes the image shift to the paper edge (0.04233 mm/step).
2. Adjustment value is able to be input within the range of 5 - 251.
The default adjustment value is 128.
Copy movement direction
100
E
01-04-08
Power ON
0
5
SET
Digital Keys
SET
INT
START
INT
Power OFF
(Set the value)
(Test copy)
(Code)
3
0
6
or
START
or
START